Skip to Main Content

I6C240FS6FS6 - 3/8" x 20' Propane Heater Hose Assembly - Vapour Only

Packaging: 1 per each
$61.86/ea

Usually ships within 3-5 business days

SKU: HOSLPG38-20 Categories: ,

OVERVIEW

Technical Overview of the 3/8" Propane Vapour Hose Assembly

The HOSLPG38-20 is a specialized hose assembly designed for the transfer of propane vapour in temporary heating applications. Engineered to meet the demands of construction environments, this hose features a 3/8-inch inside diameter, providing adequate flow rates for a wide range of portable construction heaters, including salamanders and radiant units.

The assembly measures 20 feet (240 inches) in length, offering significant reach to allow for safe positioning of heating equipment relative to the fuel source. It is terminated at both ends with 3/8-inch Female Flare Swivel fittings (often designated as FS6). These swivel fittings facilitate easy installation onto standard heater inlets and regulator outlets without twisting the hose, reducing stress on the connection points and prolonging the life of the assembly.

Constructed with a robust synthetic rubber tube and cover, the hose is resistant to the chemical effects of LP gas as well as external abrasion and weathering. The reinforcement layer ensures the hose maintains its integrity under standard operating pressures for propane vapour service. Note: This hose is rated for vapour service only and should not be used for liquid propane withdrawal applications.

Key Specifications:

  • ID: 3/8 inch
  • Length: 20 Feet
  • Fittings: 3/8" Female Flare Swivel (Both Ends)
  • Service: Vapour Only
Additional Information
Packaging Description:1 per each
Item:Propane Hose
Used for:Propane Vapour
Length :20 ft, 20"
Diameter (in):3/8"
Application:Construction Heaters
Fittings:3/8" Female Flare Swivel
Gas Type:Propane (LPG)

INCLUDED

  • 1x 20 ft. 3/8" Propane Hose Assembly

APPLICATIONS

  • Construction site heating
  • Temporary heating solutions
  • Propane vapour supply for salamanders
  • Radiant heater fuel supply
  • Agricultural heating applications

FAQ

No, this hose is designed and rated for propane vapour service only. Using it for liquid propane can be dangerous.

The hose comes with 3/8" Female Flare Swivel fittings on both ends, which are standard for most construction heaters.

Yes, the hose material is designed to withstand outdoor weather conditions and cold temperatures common on construction sites.

The hose assembly is 20 feet long.

This hose is specifically specified for Propane (LPG). Always check local codes and pressure ratings before considering other gases, but we recommend it strictly for propane vapour.

Yes, depending on your heater's requirements, this hose typically connects between the regulator on the tank and the heater, or between the tank and a heater with a built-in regulator. Always follow your heater manufacturer's instructions.

The hose has an internal diameter (ID) of 3/8 inch.

Yes, the rubber construction and reinforcement provide flexibility and resistance to kinking under normal use.